Fire doors are doors with fire resistant rating. It is a part of a passive fire protection system. It help reduce instances of fire and smoke between different compartments and rooms. Fire doors are actually fire resistant and are used along with fire dampers to provide closure. When a fire door is installed it must be done so with the appropriate fire resistant fittings and should comply with fire regulations.
The door frames of the fire resistant door consist of fire and smoke seals. These along with the hardware of the door form an assembling of the door and ha a specific fire rating. A typical fire door is made up of all of the following things.
- Closing devices, these could either be manual or automatic.
- Ball bearings and hinges
- Seals made of gas
- Latching mechanisms
- Smoke seals
The seals of a fire door are fire rated. These consist of a strip which expands when heated. Gaskets which prevent the smoke from escaping. The seals on fire doors differ in physical properties. They have a different chemical composition, rate of expansion and expansion volume. The seal should complement the fire door rating.
There are also windows on a fire door. These windows have a fire rating as well. These windows are fire resistant and remain intact in case of a fire and should also be resistant to the impact created by the hose stream when dousing out the fire.

The glass could be borosilicate glass and ceramic glass. All the components which go in the making of the fire door must be regulated according to the safety standards. According to the Australian National construction code all fire doors need to be tested and approved before being installed.
The fire doors need not be incombustible. It is expected that certain parts would combusted during a fire. However the requirement is that the fires resistant portion of the door should meet the regulatory standards and offer maximum safety.
Generally fire doors are kept closed most of the time. There are few doors which are designed to stay open during normal circumstances. Regardless of how the door is operated it should be ensured that the movement of the door shouldn’t be restricted due to the presence of a door stopper. The smoke seal should be continuously checked in order to prevent fire door failures in case there is a fire.
When installing a fire door it should be ensured that the fire door must be hung properly and without any gap. The frame of the door should be filled with fire resistant material. Also care must be taken to annually inspect the doors. Care must be taken of all of the following during installation
- There should be no holes and breaks between the door and the frames
- The glazing and the glazing beads should be intact
- None of the parts should be broken or missing
- The latching hardware should be in proper working order
- The annual door inspection is the responsibility of the building owner